Waste is thermally decomposed in the primary chamber at temperatures of 800 °C +. The resulting gaseous products are completely oxidized in the secondary chamber at higher temperatures with sufficient resident time. Other specifications are as follows. A combustion chamber of waste:
* Perfectly tight door for the manual loading of waste. The loading should be Manual, Batch Load
* A burner of lighting which the use is limited to the ignition of waste.
* Frontage of loading with door seals gone up on hinges, wheel of screw plug, flexible joint, and stuffing insulating out of refractory.
* The insulation of the combustion chamber should be composed of refractory bricks, having a high content of aluminum and insulates bricks in order to assure a minimum temperature on the outside sheet metal.
* Composition of the refractory
Burning Capacity |
Max. 200kgs/h |
|
Auxiliary Fuel |
Diesel |
|
Type of Burner |
Monoblock automatic burners |
|
Temperatures |
Primary Chamber: 800°C ± 50°C Secondary Chamber: 1300°C ± 50°C |
|
Type |
Static solid hearth |
|
Material of Construction |
Mild Steel |
|
Refractory thickness |
115 mm thick |
|
Material |
Refractory bricks |
|
Insulation thickness |
50 mm thick |
|
Waste Charging |
Manual |
|
Ash Removal |
Manual |
|
Type |
Static solid hearth |
|
Material of Construction |
Mild Steel |
|
Refractory thickness |
115 mm thick |
|
Material |
Refractory bricks |
|
Insulation thickness |
50 mm thick |
|
Type |
Centrifugal |
|
Modulation |
Manual damper control |
|
Material of Construction |
Mild Steel |
|
Type of temperature controller |
Digital |
|
Finish & painting type |
Double coat |
|
Material of construction & capacity |
Mild Steel/ Plastic, suitable capacity |
|
Other Standard Accessories |
Diesel oil level indicator, piping with valves & Non-return valve |
|
Visual Checking of Fuel |
Provided |
|
No. of Burners |
2 one in primary and in secondary chamber) |
|
Type & Model |
Monoblock automatic oil fired |
|
Make |
Riello |
|
Fuel |
Diesel |
|
Fuel delivery |
10 C 20 kg/h |
|
Firing stage |
1 |
|
Thermal power |
118 C 236 kW |
|
Motor power |
240 W |
|
Pump pressure |
10 C 12 bar (standard calibration), Max. pressure 15 bar |
|
Electrical supply |
Single phase 220V, 50Hz. |
|
Material of construction |
Burnt bricks |
|
Height |
9 meters from ground level |
HICLOVER is growing brand for environmental protection field, and market share with most of Africa, Middle East, Southeast Asia countries and part of North America, Europe territory. We are trusted partner for governmental organizations, non-profit organizations, international contractors, logistics organizations, military, pet cremation business owners, etc. We have export experience more than 40 countries, including war zone like Iraq, Afghanistan, Somalia, South Sudan. Mobile: +86-13813931455(WhatsApp) Website: www.hiclover.com Email: sales@hiclover.com Email: hicloversales@gmail.com