BURNING RATE : -100-150kgs per hour
MINIMUM OPERATING TEMPERATURE : 800-1000 oC ( PRIMARY COMBUSTION )
MAX OPERATING TEMPERATURE : 1000-1200 oC ( AFTER BURNER COMBUSTION )
SECONDARY BURNING CAPACITY : COMPULSORY
DENSITY INSULATION : 50 mm high
Refractory capacity : min 114mm
HEAVY DUTY REFRACTING LINING TO WITHSATND 17500C
AVEARGE BURN OUT TIME : MAXIMUM 3HRS
FUEL TYPE : FUEL OIL ( DIESEL )
FUEL CONSUMPTION IN LTRS/HR : average 14
RESIDNECY TIME IN SECONDARY CHAMBER : 2 STAGES
Items/Model
TS150(PLC)
Picture
Principle
Waste Incineration Treatment
Burn Rate
Average 100-150 kg/hour
Feed Capacity
Average 750kg/feeding
Control Mode
PLC(Programmable Logic Controller Incinerator)
Chamber Material
High Alumina Fire Brick Wall, 1750℃ Rate
Paint for outside face
800°C Rate
Combustion Chamber
1570L
Internal Dimensions
150x100x105cm
Secondary Chamber
750L
Smoke Filter Chamber
Yes
Feed Mode
Manual
Voltage
210/230V 50/60Hz
Power
0.9Kw
Oil Consumption (Liter/hour)
Average 14(D.O)
Gas Consumption (m3/hour)
***
Temperature Monitor
Digital Display
Temperature Protection
Yes
Oil Tank
2000L
Feed Door
80x60cm
Chimney
10Meter
Chimney Type
Stainless Steel
1st. Chamber Temperature
800℃–-1000℃
2nd. Chamber Temperature
1000℃-1200℃
Residency Time
2.0 Sec.
Gross Weight
8500kg
External Dimensions
300x160x280cm(without chimney)
Tel: +86-25-8461 0201
Website: www.hiclover.com
Email: sales@hiclover.com
Email: hicloversales@gmail.com
2020-06-28

HICLOVER is growing brand for environmental protection field, and market share with most of Africa, Middle East, Southeast Asia countries and part of North America, Europe territory. We are trusted partner for governmental organizations, non-profit organizations, international contractors, logistics organizations, military, pet cremation business owners, etc. We have export experience more than 40 countries, including war zone like Iraq, Afghanistan, Somalia, South Sudan. Mobile: +86-13813931455(WhatsApp) Website: www.hiclover.com Email: sales@hiclover.com Email: hicloversales@gmail.com