Day: January 14, 2022

incinerator Medical Waste Incinerators ⋅ 2019103 Global Incinerator Equipment Market 2019 – Outlook with Manufacturers, End Users & Forecast … The Market Plan The Global Incinerator Equipment Market condition and Forecast 2019-2028. The Global Incinerator Equipment Market Report provides major … | Auto. Control Waste Incinerator & Auto. Roll Air Filter(Air Purification) Newsletter。 […]
medical waste Medical Waste Incinerators ⋅ 2019103 Global Medical Waste Management Market 2019 Extensive Study by – Stericycle (US), Sharps … Industry News Report 24 (press release) (blog) Global Medical Waste Management Market 2019 research report highlights projection of business, market growth and challenges, new innovations … Global Reprocessed Medical Devices Market – Industry […]
TS10 PLC Waste Incinerator   Outline Dimension:1.75 x 1.3 x 1.7m Weight: Ave.1500kgs Main body(Primary combustion chamber) Material:Carbon Steel Q235B+Stainless Steel 310s+refractory firebrick material(high temperature resistance up to 1750℃) Capacity: 10-20kg/batch Combustion temperature: 800-1000℃ With chamber door, oxygen supplementation wind port, burner port, temperature control and alarm device, etc. [1 unit ] Secondary combustion chamber Material:Carbon Steel Q235B+Stainless Steel 310s+refractory firebrick material(high temperature resistance up to 1750℃) Combustion temperature:1000-1200℃ With observation port, burner port, temperature control and alarm device, etc. [1 unit ] High temperature flue gas filtration chamber Material: Outside plate: Q235B, Inside acid-resisting, alkali-resisting refractory poured material. With ash door and filtration material. [1 unit ] 1# BURNER OF 1# CHAMBER Riello brand (Italy) (High quality, combustion-resisting) Fuel: Natural gas [1 unit ] 2# BURNER OF 2# CHAMBER Riello brand (Italy) (High quality, combustion-resisting) Fuel: Natural gas [1 unit ] Chimney Material: Stainless steel,304 Length: 5m ( other length as customer request) [1 unit ] Temperature control device -Thermocouple [2 unit ] Control valve [2 pcs ] Fastening and sealing elements -Bolts, nuts, washers, paper packing etc. [1 set ] Control Cabinet Rain proof type Power indicator Voltage: 220V Temperature indicator Overload protector Leakage protection device [1 set ]       Nanjing Clover Medical Technology Co.,Ltd. Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour Control Mode PLC Auto. PLC Auto. PLC […]
The incinerator control panel shall have all appropriate audible and visual alarms to ensure safe operation.  This incinerator with “PYROLYTIC” combustion must have:  1.A combustion chamber of waste:  oPerfectly tight door for the manual loading of waste. The loading should be Manual, Batch Load  oA burner of lighting which the use is limited to the ignition of waste.  oFrontage of loading with door seals gone up on hinges, wheel of screw plug, flexible joint, and stuffing insulating out of refractory.  oThe insulation of the combustion chamber should be composed of refractory bricks, having a high content of aluminium and insulates bricks in order to assure a minimum temperature on the outside sheet metal. o Composition of the refractory; Refractory concrete : . Thickness : ≥100 mm . Nature: 42% of Al203 Insulate in fibrous panels : Thickness: ≥75 mm Nature: Calcium silicate. Burner of lighting of waste, with fuel, standard mono-bloc casting guiding  plunging flame, lighting and safety of electronic ignition, permanent ventilation, electromagnetic sluice gate of regulation and isolating valve.  Plate of combustion in Carborundum, avoiding the fixing of glass and slags A chamber of post combustion of gases  oA burner of combustion of gases,  oA device of injection of air allowing a total recombustion of gases,  oA device of air inlet of cooling of waste gases,  oA sheath of evacuation of the gases burnt.  oCarcass in strong sheet steel with support of connection.  oComposition of the refractory; Refractory concrete : Thickness : ≥150 mm Nature: 65% of Al203 Insulate in fibrous panel : Thickness: ≥85 mm  Nature: Calcium oBurner with fuel, mono-bloc casting guiding type with horizontal flame, lighting and safety of electronic ignition, permanent ventilation, electromagnetic sluice gate of regulation and isolating valve.  oA secondary injection of air to ensure perfect oxygen content.  A control box ensuring the complete cycle of combustion.  Fan:  oElectro-ventilator distributing the secondary air, the regulation of the air flow being carried out by valves and following the control of the automatic cycle.  Controls and regulations:  Control box watertight to dust, including:  A switch circuit breaker for each engine (ventilators and burners).  A timer with adjustable temporization for the regulation of each burner.  A regulator with digital watching for the temperature of combustion.  A regulator with digital watching for the temperature of post combustion.  Electric box The secondary combustion chamber must destroy the contaminant product and must resist to high temperature(1100 °C) Process Filtering system: Scruber to be mentionned as optional Emission Standards Compliance: BS 3316 or équivalent standard Capacity to treat Plastic: Not less than 40% by weight