Test shall be conducted by factory authorized representative of incinerator manufacturer.

 

  1. Demonstrate required weight reduction of specified waste. Waste shall be fed in a single batch to the unit.

After termination of manufacturer’so-called burning period, inspect and weigh the residue.

 

  1. Emissions testing may be deleted if not required by state or local authorities. List all additional tests

required by state and local emission authorities.

 

  1. Emissions:

 

  1. Test shall be conducted by independent testing organization provided by Contractor which has a minimum of three

years experience in emissions testing and that has been approved by the pollution control authority which has

jurisdiction.

 

  1. Conduct tests during the reduction of waste test specified above.

 

  1. Test methods must comply with EPA Reference Method 5, 40 CFR 60, Appendix B, “Determination of Particulate

Emissions from Stationary Sources”.

 

  1. Demonstrate that incinerator complies with specified emission limits.

 

  1. Sound Levels: Demonstrate conformance to sound level limitation.

 

  1. Report: Furnish complete written report (three copies), which includes test data, calculations, results

compared with requirements, list of personnel, and other pertinent information. Furnish report within three weeks of

test date.

Ecwid

HICLOVER is growing brand for environmental protection field, and market share with most of Africa, Middle East, Southeast Asia countries and part of North America, Europe territory. We are trusted partner for governmental organizations, non-profit organizations, international contractors, logistics organizations, military, pet cremation business owners, etc. We have export experience more than 40 countries, including war zone like Iraq, Afghanistan, Somalia, South Sudan. Mobile: +86-13813931455(WhatsApp) Website: www.hiclover.com Email: sales@hiclover.com Email: hicloversales@gmail.com