medical incinerator design

Categories:2022

It’s anticipated that the Bidder will cooperate closely with PATH and target Hospitals for the new waste management

building/area and will make available all needed technical information, drawings, etc.,

 

The following waste streams shall be treated in the new HCW treatment center(s):

 

Infectious waste

 

Sharps waste

 

Pathological waste

 

Pharmaceutical waste including cytotoxic or genotoxic waste

 

Small amounts of chemical waste

TECHNICAL SPECIFICATION FOR PROCUREMENT OF”MEDICAL WASTE TREATMENT PLANT”

Lot-A

Specification

1. Hydroclave for Medical waste Treatment Plant: Quantity: 02 Nos.

General Requirements

The chip must be accepted to purge & treat the following types of medical waste:

-Liquids: Blood, body fluids .

-Blood bags & tubing, gloves, Gowns, drapes, etc..

-Sharps & Sharp containers

-Disposable instruments

-Glass products

-Human and animal tissue (surgical and pathologic) –Based upon MWM regulations

-Cultures, stocks and glassware

The chip must comply with a documented efficacy level of 6log10 decrease in spore survival (99,9999%) of the

Bacillus Stearothermophilus

The chip should reduce the volume of the waste by 60% to 80% through complete dehydration and sterilization of

the waste

The  chip must have ZERO harmful emission level and meet or exceed all criteria required by the EU.

The whole waste treatment system should be offered as a complete unit consisting of following equipment and

ancillaries-

(A)The sterilization processing unit

(B)Steam Boiler

(C)Tub washer

(D)Heavy duty external shredder-

(E)Conveyer belt-based on Manufacturer’s Recommendations

(F)Bin Lift/Tipper

(G)Spore tester

(A)Features and Specifications of the Sterilization Processor unit:

Technical specification of the chip:

Steam autoclave in combination with a heavy duty Fragmenting System within the vessel/chamber

The boat must be of Double Chamber

Ability (kg/load): minimum 200 kg/batch/cycle

Volume of 140-190 liters of bulk per cycle

Average Cycle time: 60 minutes

Operating temperature: 121◦C to 135◦C

Running pressure: 1.1 Bar to 2.4 Bar

Operating pressure : 1.1 Bar to 2.4 Bar

Ecwid

HICLOVER is growing brand for environmental protection field, and market share with most of Africa, Middle East, Southeast Asia countries and part of North America, Europe territory. We are trusted partner for governmental organizations, non-profit organizations, international contractors, logistics organizations, military, pet cremation business owners, etc. We have export experience more than 40 countries, including war zone like Iraq, Afghanistan, Somalia, South Sudan. Mobile: +86-13813931455(WhatsApp) Website: www.hiclover.com Email: [email protected] Email: [email protected]